1.2.1 Circuit Protection¶
Overview¶
START battery positive circuits are protected in two places:
- Battery post — Blue Sea MRBF terminal fuses mounted directly on the START+ post (PMU, Forward Distribution Bus master, BCDC input)
- Engine bay — Mechanical Products Series 17 circuit breakers and inline fuses at the START+ Forward Distribution Bus
Battery-Post Terminal Fuses (MRBF)¶
Blue Sea Systems MRBF terminal fuses (30–300 A, 10,000 A AIC @ 14 V DC, ignition protected) sit on the battery post in a terminal fuse block — dual block 2151 for PMU + forward bus, single block 5191 for BCDC.1 Part numbers to confirm at order: TBD #331.
| Circuit | Fuse | Wire | Power Path | Max Load | Sizing |
|---|---|---|---|---|---|
| PMU24 | 150A MRBF | 1 AWG | START battery+ └→ 150A MRBF └→ PMU24 battery stud |
85–115A typical; 150A stud max | Matches the PMU battery stud's 150 A constant limit;2 1 AWG @ 150A, ~7 ft, 60°C-derated ≈ 2.6% drop (2.0% at 115A typical) — downsized from 2/0 + 250A CB (2026-10-17) |
| Fwd Dist Bus (master) | 100A MRBF | 2 AWG | START battery+ └→ 100A MRBF └→ START+ Forward Distribution Bus |
~62A continuous / ~102A brief peak | At or below the 2 AWG ampacity (110A @ 60°C); the brief ~102A peak is inside the MRBF time-current curve;1 selective with the downstream load CBs |
| BCDC Input | 80A MRBF | 4 AWG | START battery+ └→ 80A MRBF └→ BCDC Alpha 50 |
50–55A BCDC input | 145–160% of max load |
Total battery-post fuses: 3 (PMU 150A, Forward Dist Bus master 100A, BCDC 80A)
Why terminal fuses instead of inline CBs: one joint per circuit instead of three (lug→CB in, CB out→lug), no stacked ring lugs beyond the block, and the within-7"-of-post rule is satisfied by mounting on the post itself. Fuses are not resettable — carry spares. Replaces the three Mechanical Products Series 17 inline CBs (174-S2-250-2, 174-S2-100-2, 174-S2-080-2) at the START battery (2026-10-17).
Forward Distribution Bus Breakers (engine bay)¶
Loads on the START+ Forward Distribution Bus (engine bay) are each protected at the bus, fed from the 100A master MRBF above. The two heavy loads use Mechanical Products Series 17 breakers (SKUs follow the S2 pattern — confirm via TBD #135); the two light loads use ATO/ATC inline fuse holders at the bus.
| Circuit | Model | Rating | Power Path | Max Load | Sizing |
|---|---|---|---|---|---|
| Radiator Fan | Mechanical Products (174-S2-060-2) | 60A CB | Fwd Bus → 60A CB → fan | 53A continuous | 113% of max load (protects 4 AWG) |
| iBooster main | Mechanical Products (174-S2-050-2) | 50A CB | Fwd Bus → 50A CB → iBooster | 40A brief peak / 0.25A idle | 125% of brief peak (protects 8 AWG) |
| CT4 12V supply | ATO/ATC inline fuse holder | 15A fuse | Fwd Bus → 15A fuse → HDP24 pin 2 → CT4 | ~9A | Protects 14 AWG; size-16 contact 13A |
| PBS-I battery +12V | ATO/ATC inline fuse holder | 5A fuse | Fwd Bus → 5A fuse → HDP24 pin 22 → PBS-I RED | Standby ~50 mA standby estimate accepted into the START key-off parasitic budget (≈1.2 Ah/day, ~28 days to 50% SOC on the 68 Ah PC1500) — no impact on wire gauge or part selection. #84 | Protects 14 AWG |
Total Forward Bus protection: 2 CBs (fan 60A, iBooster 50A) + 2 inline fuses (CT4 15A, PBS-I 5A). The TCU moved back to PMU OUT15 (2026-10-17); its 25A bus CB is deleted.
Series 17 Circuit Breakers (engine bay, 2 units):
- Manufacturer: Mechanical Products Series 17
- Type: Surface mount
- Reset: Manual (Type III - push to reset)
- Terminals: 3/8"-16 studs (S2 configuration)
- Dimensions: 3.39" L × 1.9" W (per unit)
- Ratings: 48V DC (20-150A), 30V DC (175-200A), 14V DC (225-300A)
- Standards: Marine-rated (SAE J1171, ABYC E-11, UL1500, IP67, MIL-STD-202)
- Mounting: Engine bay, on a bracket beside the Forward Distribution Bus
Space Requirements: The MRBF blocks mount on the START+ post (no wheel-well bracket needed). The 2 forward-bus load CBs plus 2 fuse holders mount in the engine bay beside the Forward Distribution Bus, not in the wheel well.
Related Documentation¶
- START battery Distribution Overview
- PMU Outputs - Load details for PMU circuit (Dakota Digital, TCU, communication systems, etc.)
- BCDC Alpha 50 - DC-DC charger specifications
- Communication Systems - Radio and intercom specifications (now PMU powered)
-
Blue Sea Systems MRBF terminal fuse: 30–300 A, interrupt 10,000 A @ 14 V DC, ignition protected; requires terminal fuse block 5191 (single) or 2151 (dual). https://bluesea.com/products/5184 and https://defender.com/en_us/blue-sea-systems-dual-mrbf-terminal-fuse-block-2151 (accessed 2026-10-17). Part numbers to confirm at order (TBD #331). ↩↩
-
ECUMaster, PMU-24 DL Pinout v1.1 (2023-10-06): battery stud "Maximum constant current: 150 A"; O1–O5, O12–O16 25 A; O6–O11 15 A; O17–O24 7 A; terminals 211CC2S2160P 13–17 AWG, 211CC3S2120 14–16 AWG, 211CC3S3120 10–12 AWG. https://www.ecumaster.com/files/PMU/PMU-24_Pinout_v1.1.pdf (accessed 2026-10-17). ↩