Dome Lights¶
Roll bar-mounted interior lighting for cabin illumination.
Specifications¶
Type: KC HiLiTES Cyclone V2 Quantity: 4 pods Output: 200 lumens each (800 total) Draw: 0.5A each (2A total) Size: 2.4" diameter round Part #: 1352 (single light) Wire Gauge: 16 AWG
Mounting Bracket: KC HiLiTES Dual Cyclone Dome Light Mount (#6337)
- ADC12 aluminum, powder coated black
- Roll cage mount design
- Includes hardware and switch
- Dimensions: 5.45" W × 2.61" D × 1.54" H
Control¶
Controller: SwitchPros Button 4 (OUTPUT-4)
- Manual: Button 4 press
- Automatic: Door switches via TRIGGER-1
See SwitchPros SP-1200 for wiring and trigger configuration.
Mounting¶
- 2x front roll bar (above driver/passenger seats)
- 2x rear roll bar (above rear cargo area)
Rear Seat Override¶
Physical switch on KC #6337 bracket for rear dome control independent of SwitchPros panel.
Wiring: KC bracket switch wired in parallel with SwitchPros OUTPUT-4:
- KC switch input: 12V CONSTANT (tap from SwitchPros power input or BODY PDU)
- KC switch output: Rear dome lights positive (parallel with SwitchPros OUTPUT-4)
- Either switch can turn on rear domes independently
Backfeed risk — isolation design pending
As drawn, the CONSTANT-fed override tap is wired in parallel with OUTPUT-4 with no isolation diode. When the override switch is on, 12V CONSTANT backfeeds into OUTPUT-4 regardless of the SwitchPros state. Isolation design is pending — TBD #148.
Outstanding Items¶
📋 Medium (2)
- Front turn signal LED marker part selection (#153) — The turn-signals page documents front amber LED turn signals (qty 2, fender-mounted, ~0.8" × 0.8" × 1.1" envelope, CT4 SW1/SW2) with Part #: N/A. No part number exists anywhere in the docs and there is no purchase-tracker row — the wiring will be complete with no physical light to connect.
- Dome light rear-seat override: isolation needed to prevent backfeed into SwitchPros OUTPUT-4 (#148) — The rear-seat override wires the KC #6337 bracket switch in parallel with SwitchPros OUTPUT-4, fed from a 12V CONSTANT tap, with no isolation. Consequences as drawn: dome lights stay energized via the constant tap regardless of OUTPUT-4 state, and constant voltage is injected into the de-energized SP-1200 output.
Build Tasks¶
- Plan wire routing from SwitchPros to roll bar mounts