SwitchPros SP-1200 (RCR-Force 12)¶
Model: RCR-Force 12
Manual: https://www.switchpros.com/wp-content/uploads/RCR-force-12-installation-guide-REV-1.9.pdf
Power Source: 150A breaker from Firewall CONSTANT Bus (fed from AUX battery via 250A MRBF terminal fuse at the post + 2/0 AWG forward feed)
Power Wire: 2 AWG, ~2 ft (Firewall CONSTANT Bus to power module — both at firewall cluster)
Power Module Location: Firewall (cabin side, passenger area) — co-located with BODY PDU and Firewall CONSTANT Bus. Module is IP67 / 125°C-rated so wheel well placement is also valid, but firewall mounting minimizes total output wire length since most loads are forward/upper (~58% of outputs).
Control Panel Location: Center console top plate, directly behind the Kilduff shifter (owner, 2026-09-25). The panel is 4.0 x 3.0 x 0.375 in. It mounts either in a 3.875 x 2.875 in bezel cutout with 0.237 in corners, or on a flat surface on its 6-32 studs.2
Control Cable: Not yet ordered. The 5 ft size was picked for a firewall-to-dash run, and the run from the firewall to the console is longer. SwitchPros sells the cable in 5 ft steps from 5 to 50 ft and says to add 6 in for strain relief.3 Measure the route before ordering.
Ground: 4 AWG to chassis (per manufacturer spec - reference ground only, not load return)
Load Ground Path
The 4 AWG controller ground is for logic/reference only. Load return current flows through individual output grounds to the SwitchPros Ground Bus (1/0 AWG to chassis).
IP Rating: IP67 (both power module and control panel)
Overview¶
Specifications:
- 150A total capacity on CONSTANT bus
- 17 outputs total:
- 4 outputs @ 35A (high in-rush circuits)
- 1 output @ 30A (high in-rush)
- 11 outputs @ 15A (can be combined for larger loads)
- 1 low-side driver @ 2A
Control Panel Layout¶
| Button | Circuit | Draw | Details | Output Pin(s) |
|---|---|---|---|---|
| 1 | Roof Lights | 17.6A | 8x BD XL Sport (Linkable, single circuit) | OUTPUT-1 |
| 2 | Ditch Lights | 8A | 2x BD LP4 Pro (Driving/Combo Pattern) | OUTPUT-2 |
| 3 | Fog Light | 6A | 1x BD S8 10" (Amber, Wide Cornering) | OUTPUT-3 |
| 4 | Dome Lights | 2A | 4x KC Cyclone V2 (manual + door-triggered) | OUTPUT-4 |
| 5 | Interior LEDs | 5A | MLC-RW controller (speaker + footwell RGB) | OUTPUT-5 |
| 6 | Rock Lights | 3A | 6x KC Cyclone V2 Lights | OUTPUT-6 |
| 7 | Chase Light | 1A | BD RTL-S 30" (Amber chase mode) | OUTPUT-7 |
| 8 | Spare | - | Freed 2026-09-24: GPS moved to PMU OUT14 (ignition) | OUTPUT-8 (spare) |
| 9 | Spare | - | Freed 2026-09-24: front locker moved to a dash switch | OUTPUT-17 (spare, low-side) |
| 10 | Spare | - | Freed 2026-09-24: rear locker moved to a dash switch | OUTPUT-10 (spare) |
| 11 | Compressor | 15A | ARB Twin Compressor (see Air System) | OUTPUT-11 |
| 12 | Rear Work Lights | 5A | 2x BD S1 Black (Above License Plate) | OUTPUT-12 |
Notes:
- Button 4: Dome lights have dual control - Button 4 OR the rear-seat switch via TRIGGER-1
- Rear-seat switch (latching, closes to ground) → TRIGGER-1 → OUTPUT-4
- Either one turns the dome lights on. There are no door switches: the Jeep has none, and it runs half doors or no doors (owner, 2026-09-24).
- Button 7: RTL-S amber chase function only - brake/running/work functions powered separately
- Button 11: OUTPUT-11 provides control signal to ARB compressor (main power is separate: CONSTANT bus → dual 60A fuses → compressor)
- Cargo Light: Not assigned to button - controlled by rear rocker switch via TRIGGER-2 → OUTPUT-13 (power source conflict with BODY PDU CB20 — see ⚠️ TBD #147)
- Total lighting draw if all on simultaneously: 43.6A (within 150A capacity)
Wiring Pinout¶
20-Pin Harness Connector¶
| Pin | Label | Color | Gauge | Max Load | Assigned Circuit | Load | Notes |
|---|---|---|---|---|---|---|---|
| 1 | OUTPUT-5 | GREEN | 14 AWG | 15A | Interior LEDs (MLC-RW controller) | 5A | |
| 2 | OUTPUT-6 | BLUE | 14 AWG | 15A | Rock Lights | 3A | |
| 3 | IGNITION | LT BLUE | - | - | Connect to ignition signal | - | For auto-off features |
| 4 | LIGHTS | WHITE | - | - | PMU Out 12 parking/tail circuit (tap at firewall) | - | Parking-light sense — see DRL & Parking |
| 5 | OUTPUT-7 | PURPLE | 14 AWG | 15A | Chase Light (amber) | 1A | RTL-S amber chase function only |
| 6 | OUTPUT-8 | GREY | 14 AWG | 15A | SPARE | - | GPS moved to PMU OUT14 (2026-09-24) |
| 7 | TRIGGER-1 | PINK | - | - | Rear-seat dome switch (Blue Sea 4160) | - | Active low; triggers OUTPUT-4 (dome lights) |
| 8 | TRIGGER-2 | PINK | - | - | Rear cargo rocker switch | - | Triggers OUTPUT-13 (cargo light) |
| 9 | OUTPUT-9 | WHITE | 14 AWG | 30A (2x15A) | SPARE (can combine 9+10) | - | |
| 10 | OUTPUT-9B | WHITE | 14 AWG | - | SPARE (fused with 9) | - | |
| 11 | OUTPUT-10 | TAN | 14 AWG | 15A | SPARE | - | Rear locker moved to a dash switch (2026-09-24) |
| 12 | OUTPUT-11 | BROWN | 14 AWG | 15A | Compressor control | 15A | Control signal to compressor |
| 13 | OUTPUT-12 | RED | 14 AWG | 15A | Rear Work Lights | 5A | |
| 14 | GROUND | BLACK | - | - | Direct to battery negative | - | Critical - direct connection |
| 15 | OUTPUT-13 | ORANGE | 14 AWG | 15A | Cargo Light | 5A | Triggered by rear rocker switch (TRIGGER-2) |
| 16 | OUTPUT-14 | YELLOW | 14 AWG | 15A | SPARE | - | |
| 17 | TRIGGER-3 | PINK | - | - | ARB pressure switch | - | Auto compressor control |
| 18 | OUTPUT-17 | LT GREEN | - | 2A | SPARE (low-side) | - | Front locker moved to a dash switch (2026-09-24) |
| 19 | OUTPUT-15 | GREEN/BLACK | 14 AWG | 15A | SPARE | - | |
| 20 | OUTPUT-16 | BLUE/BLACK | 14 AWG | 15A | SPARE | - |
4-Pin Harness (High Current Outputs)¶
| Pin | Label | Color | Gauge | Max Load | Assigned Circuit | Load | Notes |
|---|---|---|---|---|---|---|---|
| 1 | OUTPUT-1 | BROWN | 10AWG | 35A | Roof Lights (8x) | 17.6A | |
| 2 | OUTPUT-2 | RED | 10AWG | 35A | Ditch Lights | 8A | |
| 3 | OUTPUT-3 | ORANGE | 10AWG | 35A | Fog Light | 6A | |
| 4 | OUTPUT-4 | YELLOW | 10AWG | 35A | Dome Lights | 2A |
Power and Ground Connections¶
See AUX Battery Distribution for source battery and Firewall CONSTANT Bus for downstream distribution.
- Power: AUX battery+ → 250A MRBF terminal fuse → 2/0 AWG forward (~13 ft) → Firewall CONSTANT Bus → 150A CB → SwitchPros power module
- Ground (logic reference): 4 AWG wire from SwitchPros power module → chassis ground at firewall (short run, per manufacturer spec)
- Load returns: Each output's ground wire returns to the SwitchPros Ground Bus (Blue Sea 2105 MaxiBus), co-located with the power module at the firewall
Trigger Input Assignments¶
TRIGGER-1: Rear-Seat Switch → Dome Lights¶
Switch Type: Blue Sea 4160 latching push button, used as a signal switch. It closes TRIGGER-1 to ground and carries no lamp current.
Wiring:
Wire Routing: Rear-seat switch location (⚠️ TBD #77) → cabin → firewall SwitchPros. 18 AWG (signal only).
Configuration:
- Set TRIGGER-1 to active low in the app. The RCR-Force 12 triggers can be set to active high or active low.1
- Program TRIGGER-1 → OUTPUT-4. Button 4 still switches OUTPUT-4 by hand.
This replaces the parallel, CONSTANT-fed override that would have backfed OUTPUT-4. See Dome Lights.
TRIGGER-2: Rear Rocker Switch → Cargo Light¶
Physical rocker switch mounted in rear cargo area.
Wiring:
Configuration:
- Program TRIGGER-2 → OUTPUT-13 (cargo light)
TRIGGER-3: Air Pressure Switch → Auto Compressor Control¶
Wiring:
Configuration:
- TRIGGER-3 OR Button 11 → OUTPUT-11 (compressor)
- When tank pressure < 135 PSI: TRIGGER-3 closes → OUTPUT-11 activates → compressor runs
- When tank pressure = 150 PSI: TRIGGER-3 opens → OUTPUT-11 deactivates → compressor stops
- Manual override: Button 11 can force compressor on regardless of tank pressure
Signal Source:
- ARB Pressure Switch model 180901 (cut-in: 135 PSI, cut-out: 150 PSI)
- Mounted on air manifold under passenger seat
- Low current signal wire (18 AWG from manifold under passenger seat to SwitchPros TRIGGER-3 at firewall — short run)
Related Documentation:
- See Air System for complete ARB compressor, tank, and pressure switch specifications
Outstanding Items¶
TBD tracker unavailable
Could not reach the GitHub issues API at build time (network or rate limit). Set GITHUB_TOKEN to raise the limit.
Build Tasks¶
Check-off items only. Pin assignments and wire gauges live in the Wiring Pinout section above; controller mounting, power feed, and ground bus install are tracked in the Power Systems Checklist.
Triggers & Programming:
- Confirm ignition signal → SwitchPros Pin 3 (IGNITION)
- ~~Determine parking-lights signal source for Pin 4 (LIGHTS)~~ → Resolved 2026-09-22: PMU Out 12 parking/tail circuit, tapped at the firewall
- Measure the control cable route (power module on the firewall to the console) and order the cable
- Install rear-seat dome switch → TRIGGER-1 (active low)
- Program Button 4: OUTPUT-4 OR TRIGGER-1 → dome lights
- Install rear cargo rocker switch → TRIGGER-2 (determine tailgate-accessible location)
- Program TRIGGER-2 → OUTPUT-13 (cargo light)
- Confirm cargo light wiring (OUTPUT-13) — power-source conflict pending ⚠️ TBD #147
- Confirm ARB pressure switch → TRIGGER-3
- Program TRIGGER-3 OR Button 11 → OUTPUT-11 (compressor auto/manual)
- Test automatic pressure control (compressor on/off at setpoints)
- Assign spare outputs: OUTPUT-8, 9, 10, 14, 15, 16 and low-side OUTPUT-17 (buttons 8, 9, 10 are free)
Related Documentation¶
- Control Interfaces Overview
- Offroad Lighting - Complete wiring details for all lighting circuits controlled by SwitchPros
- Air System - ARB compressor wiring details (the lockers now run from dash switches)
- AUX Battery Distribution - Power feed specifications for SwitchPros
-
SwitchPros RCR-Force 12 installation guide (Rev 1.9), pp. 4 and 7: trigger inputs "can be programmed to trigger on an active high (>4.5V) or active low" signal. https://www.switchpros.com/wp-content/uploads/RCR-force-12-installation-guide-REV-1.9.pdf (accessed 2026-09-24). ↩
-
SwitchPros RCR-Force 12 installation guide (Rev 1.9), p. 9 (flat-surface mount on the 6-32 studs, or a 3.875" x 2.875" bezel opening with a 0.237" corner radius) and p. 14 (switch panel size: width 3.0", length 4.0", height 0.375"). https://www.switchpros.com/wp-content/uploads/RCR-force-12-installation-guide-REV-1.9.pdf (accessed 2026-09-25). ↩
-
SwitchPros, "RCR-Force 12 Twelve Switch Remote Panel System" store page: cable lengths 5' to 50' in 5' steps, "add a 6 inch allowance for strain relief". https://store.switchpros.com/rcr-force-12-twelve-switch-remote-panel-system/ (accessed 2026-09-25). ↩