1.4 PMU Power Distribution

Engine bay power distribution handled by ECUMaster PMU24, a programmable power management unit with 24 outputs replacing traditional relay/fuse panels.

Location: Engine bay

Power Connections

Connection Source Wire Gauge Protection Notes
Main Power START battery+ 1 AWG, ~7 ft 150A MRBF terminal fuse at the START post PMU battery stud is 150 A max constant1; ≈2.6% drop at 150A (60°C-derated), ≈2.0% at 115A typical. Downsized from 2/0 + 250A CB (2026-10-17) - See Circuit Breakers
Ground Engine Bay Ground Bus stud 5 12 AWG (connector pin 25) N/A Logic reference only, as short as possible; load current returns through each load's own ground - See Grounding Architecture
Ignition Sense Ignition signal bus bar (engine bay distribution off HDP24 Pin 12) 18 AWG (16 AWG pigtail at PMU) N/A Sourced from PBS-I PINK IGN via the cabin ignition bus bar; PMU switches off when it drops, except for the Delayed turn off window that keeps the TCU (OUT15) alive - see PMU Inputs, PMU Programming and Keyless Ignition
CAN Bus Cummins ECM J1939 18-20 AWG twisted pair (16 AWG pigtail at PMU) N/A Stub tap - see PMU Inputs

System Components

  • 1.4.1 - Overview - Product specifications, capacity analysis, features, mounting
  • 1.4.2 - Inputs - Digital/analog inputs, CAN bus integration, ignition distribution
  • 1.4.3 - Outputs - 24-output configuration, load analysis, combined outputs
  • 1.4.4 - Programming - Logic examples, sequential startup, configuration, outstanding items

  1. ECUMaster, PMU-24 DL Pinout v1.1 (2023-10-06): battery stud "Maximum constant current: 150 A"; O1–O5, O12–O16 25 A; O6–O11 15 A; O17–O24 7 A; terminals 211CC2S2160P 13–17 AWG, 211CC3S2120 14–16 AWG, 211CC3S3120 10–12 AWG. https://www.ecumaster.com/files/PMU/PMU-24_Pinout_v1.1.pdf (accessed 2026-10-17). ↩